Liên hệ
Category 6a• Class Ea, link/channel up to 500MHz• Up to 10GBASE-T, 100m• Typical 23AWG Solid conductor size• High alien-Cross-talk performance in higher freq.• Used primarily in enterprise and datacenters• Unshielded and Shielded version• CM and LSZH jacket
Category 6• Class E, link/channel up to 250MHz• Up to 10GBASE-T , 55m max.• Typical 23/24AWG Solid conductor size• More stringent in Cross-Talk and system noise• Used primarily in premises & enterprise• Unshielded and Shielded version• CM, CMR and LSZH jacket
Category 5e• Class D, link/channel up to 100MHz• Up to 1000BASE-T• Typical 24AWG Solid conductor size• 25 watts carrying for POE applications• Used primarily in premises.• Unshielded and Shielded version• PVC and LSZH Jacket• Outdoor Jacket available
• Light weight• Sleek design & feel• Water paint• Easy fixtures• Abrasion resistance• Highly durable• Easy fix-up to 8 module cassettes• Easy fix-up to 8 adaptor panels• Up to 192 fibres (MPO configuration)
• Light weight• Sleek design & feel• Water paint• Drawer for easy installation and maintenance• Abrasion resistance• Highly durable• Easy fix-up to 4 module cassettes• Easy fix-up to 4 adaptor panels• Up to 96 fibres (MPO configuration)
• Light weight• Sleek design & feel• Water paint• Easy fixtures• Abrasion resistance• Highly durable• Easy fix-up to 4 module cassettes• Easy fix-up to 4 adaptor panels• Up to 96 fibres (MPO configuration)
Central strength member (CSM): steel wire with plastic coating whenneeded. Tube: thermoplastic material, containing up to 12 optical fibres andfilled with a suitable water tightness compound. Stranding: The required numbers of elements (tubes or fillers) are SZstranded around the central strength member. Longitudinal Water Tightness: WB tape and water blocking yarn (drycore) Inner Sheath: LSZH. Armour: Corrugated steel tape. Outer Sheath: LSZH. Compliant to IEC60332-3-24, IEC60332-1,IEC60754-1/2, IEC61034-2, UL1581 UV Resistant. Suitable for Direct Buried or Indoor/Outdoor Installation.
Unitube: thermoplastic material, containing up to 24 fibres and filledwith a suitable water tightness compound. Peripheral Strength Elements: Aramid yarns. Armour: corrugated steel tape. Outer Sheath: LSZH Compliant to IEC60332-3-24, IEC60332-1, IEC60754-1/2, IEC61034-2, UL1581 UV Resistant. Suitable for Duct Buried or Indoor/Outdoor Installation
Unitube: thermoplastic material, containing up to 24 fibres and filled with asuitable water tightness compound. Peripheral Strength Elements: Aramid yarns. Armour: corrugated steel tape. Outer Sheath: PE. Suitable for Direct Buried and Outdoor Installations
Central Strength Member: FRP with up-coating when needed Tight buffer: Each fibre is coated to 0.9mm with PVC Strength Member: Aramid yarn within each sub-unit Sub-unit sheath: PVC Core Wrapping: Polyester tape Outer Sheath: PVC Complaint to UL OFNR, suitable for indoor installation requiring riserapplication
Tight buffer: Each fibre is coated to 0.9mm with PVC. Strength Member: Aramid yarn. Outer Sheath: PVC, Complaint to UL OFNR Suitable for indoor installation requiring riser application